{"product_id":"timer-relay-6-to-30v-adjustable-timer-delay-timer","title":"Digital Led Display Programmable Circuit Egg Incubator Timer Relay Module Controller Ws16","description":"\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eDigital Incubator Timer Relay \u003c\/strong\u003eis a timer relay suitable for your incubator and other time-related projects. The \u003cstrong\u003etimer relay\u003c\/strong\u003e \u003cstrong\u003emodule \u003c\/strong\u003eis a Digital display Led Home Automation Delay Timer Control Switch Module Timer Controller, Operating voltage: 6-30V, support micro USB 5.0V power supply, Output capability: Can control the device within DC 30V 5A or AC 220V 5A.  This\u003cstrong\u003e best incubator timer controller\u003c\/strong\u003e can be applied to many fields; there is a wide range of applications. Programmable Triggered Timing Circuit board 35238mp.\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003ch2\u003e\u003cstrong\u003eFeatures Of 35238mp HW-521 Circuit Incubator Egg Turner Timer Relay Switch Control Module:\u003c\/strong\u003e\u003c\/h2\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003e \u003cspan style=\"font-size:14px;\"\u003eWide voltage power supply (6 ~ 30V), supports micro USB 5.0V power supply, easy to use;\u003c\/span\u003e\n\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e The interface is clean, simple, powerful, and easy to understand, can meet almost all your needs;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e With emergency stop function (“STOP” button) and reverse polarity protection which can avoid burning by reverse connection.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e Adding sleeping mode, when the mode is enabled, if there is no operation within 5 minutes, the display will be turned off automatically, press any button will wake it up;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e You can set different parameters of OP, CL, LOP, which are independent of each other and are stored separately;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cspan style=\"font-size:14px;\"\u003e All the parameter settings will be stored automatically when power is off.\u003c\/span\u003e \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch2\u003e\u003cstrong\u003eSpecifications Of Timer circuit Incubator Egg turner 6-30V Relay Module Switch Trigger Time Circuit Timer Cycle Adjustable:\u003c\/strong\u003e\u003c\/h2\u003e\r\n\r\n\u003col\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eOperating voltage: \u003c\/strong\u003e6-30V, support micro USB 5.0V power supply\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eTrigger signal source:\u003c\/strong\u003e Active-high (3.0V-24V), have optocoupler isolation, can improve the system's anti-jamming capability (customers can also short common ground).\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eOutput capability:\u003c\/strong\u003e Can control the device within DC 30V 5A or AC 220V 5A.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eQuiescent current:\u003c\/strong\u003e 20mA;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eOperating current:\u003c\/strong\u003e 50mA\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eService life: \u003c\/strong\u003emore than 10 million times\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eWorking temperature: \u003c\/strong\u003e-40°c ~ 85 °c\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eDimension: \u003c\/strong\u003e62×38×17mm.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eWith optocoupler isolation, enhanced anti-jamming capability, industrial-grade board. The parameter setting will be stored forever when power is off.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eSpecial Note:\u003c\/strong\u003e The output of the replay is passive contact, without voltage output, just for controlling the on or off of a single circuit.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cspan style=\"font-size:14px;\"\u003eTiming range\u003c\/span\u003e\r\n\t\u003col\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e0.1 seconds (min.) to 999 minutes (max.) continuously adjustable\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eHow do choose the time range?\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eAfter setting the parameter values in the mode selection interface, you can choose the timing range by short pressing the \"STOP\" button;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eXXX. the decimal point is in the unit digit, timing range: 1 second to 999 seconds.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eXX. X decimal point is in the tens digit, timing range: 0.1 seconds to 99.9 seconds\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eX. X. X. decimal all light on, timing range: 1 minute to 999 minutes.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eFor example, if you want to set the \"OP\" time to 3.2 seconds,  you can move the decimal point to the place of tens digit, the digital display 03.2\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003c\/ol\u003e\r\n\t\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\r\n\u003ch2\u003e\u003cstrong\u003eOperating Mode:\u003c\/strong\u003e\u003c\/h2\u003e\r\n\r\n\u003col\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP1: Trigger signal, the relay is on \"OP\" time, and then disconnect; Within the \"OP\" time, proceed as follows:\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP1.1: signal is triggered again, invalid\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP1.2: signal is triggered again, re-clocking\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP1.3: Signal has triggered again, the relay is disconnected, stop the clock;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP-2: Trigger signal, after the \"CL\" time is off, the \"OP\" time is on. When the timing is completed, the replay will be disconnected;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP3.1: Trigger signal, after the \"OP\" time is on, the \"CL\" time is off, then cycle the above actions. If the trigger signal is within the loop, the relay will be disconnected and stop the clock. The number of cycles ( \"LOP \") can be set.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP3.2: No need to trigger the signal after powering up, the \"OP\" time is on, the \"CL\" time is off, then cycle the above actions; The number of cycles ( \"LOP \") can be set.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eP-4: Signal holding function. If the signal is triggered, timing is cleared, the relay remains on; when the signal disappears, the relay will be off when the \"OP\" time is over; if another signal is triggered during timing, timing will be cleared.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\r\n\u003ch2\u003e\u003cstrong\u003eParameter Instruction:\u003c\/strong\u003e\u003c\/h2\u003e\r\n\r\n\u003col\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\"OP\" - On-time\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\"CL\" - Off-time\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\"LOP\" - The number of cycles (1-999 times, \"---\" represents infinite cycles).\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eThese parameters are independent but are shared by each mode. For example, in P1.1 mode, the on-time \"OP\" is set 5 seconds. If you switch to P1.2 mode, the \"OP\" time of P1.2 mode will be 5 seconds too.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eIn the main interface (display 000), short press the \"SET\" button, it will display \"OP\" ( \"CL\", \"LOP\") and the corresponding time XXX;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eIf there is only \"OP\" time in some modes (such as the mode P1.1, P1.2, P1.3), short press the \"SET\" button to display the “OP” and the corresponding time only;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eThere are \"OP\", \"CL\", \"LOP\" in some modes (such as the mode P3.1, P3.2), short press \"SET\" button will display \"OP\" and the corresponding time, “CL” and the corresponding time, “LOP” and the corresponding number of times;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eAfter setting the mode, short press the \"SET\" button can check all the set parameters of the mode at present in the main interface, easy and convenient!\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eHow to set parameters?\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e1. Determine the operating mode of the relay.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e2. The current operating mode (P1.1 mode in default) will flash when the module is powered up. Then enter into the main interface. In the main interface, long-press the \"SET\" button for 2 seconds then release to enter the mode selection interface, short press the \"UP\" or \"DOWN\" button to select the mode (P1.1 ~ P-4) you need.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e3. After selecting the operating mode (e.g. P3.2), short press the \"SET\" button to select the parameter to be set. The selected parameter will flash ( \"OP\" on-time, \"CL\" off-time, \"LOP\" cycle times ( \"---\" represents infinite cycles)), then you can adjust the values by \"UP\", \"DOWN\" button to adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease one unit). After finishing adjusting, short press the \"STOP\" button to select the position of the decimal point, select the timing range (0.1 seconds to 999 minutes). Then short press the \"SET\" button to enter to set the value of the next parameters. The setting procedure is the same as above.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e4. After setting the parameters, long-press the \"SET\" button for 2 seconds then release, the name of the current mode will flash, and then return to the main interface. The parameters setting is completed.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eThe main interface: In the status that the relay is not working, the main interface will display \"000\" (no decimal point); in the status that the relay is working, there will be a decimal point.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eMode selection interface: Long press the \"SET\" button to enter into the mode selection interface, after the setting is completed, long-press the \"SET\" button to exit and return to the main screen.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\r\n\u003ch2\u003e\u003cstrong\u003e\"STOP\" button extensions:\u003c\/strong\u003e\u003c\/h2\u003e\r\n\r\n\u003col\u003e\r\n\t\u003cli\u003e\n\u003cspan style=\"font-size:14px;\"\u003eRelays enable mode:\u003c\/span\u003e\r\n\r\n\t\u003col\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e1. ON: Relay allows conduction in \"OP\" on-time;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e2. of relay prohibits conduction and is always closed;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eIn the main interface, short press the \"STOP\" button to switch between ON and OFF, the current status will flash, and then return to the main interface. (This is an emergency stop function, turn off the relay with one button)\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003c\/ol\u003e\r\n\t\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cspan style=\"font-size:14px;\"\u003eSleeping mode:\u003c\/span\u003e\r\n\t\u003col\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e1. \"C-P\" sleeping mode: If there is no operation in 5 minutes, the digital display will turn off automatically but the program will run as usual;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e2. \"O-d\" normal mode: digital display always opens;\u003c\/span\u003e\u003c\/li\u003e\r\n\t\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eLong press the \"STOP\" button for two seconds and then release to switch the mode of \"C-P\" and \"O-d\", in which the current state of flashes and then return to the main interface.\u003c\/span\u003e\u003c\/li\u003e\r\n\t\u003c\/ol\u003e\r\n\t\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\r\n\u003ch2\u003e\u003cstrong\u003e Package Includes:\u003c\/strong\u003e\u003c\/h2\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x Relay Module (Relay Control Switch) Model 35238mp HW-521  \u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003eBest online shopping website for Digital LED Display Programmable Circuit Egg Incubator Timer Relay Module Controller Best High-quality Timer at cheap price in Lahore Faislabad Multan Quetta Sargodha Rahim Yar Khan Sialkot Sahiwal Gujrat Attock Gojra Sheikhpura Jahng Khanewal Okara Kasur Karachi and all over Pakistan.\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/digilog.pk\/cdn\/shop\/files\/Digital-LED-Display-Programmable-Circuit-Egg-Incubator-Timer-Relay-Module-Controller-Lahore-Faislabad-Multan-Quetta.webp\" alt=\"Digital Led Display Programmable Circuit Egg Incubator Timer\" loading=\"lazy\" data-original=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0744\/0764\/1366\/files\/Digital-LED-Display-Programmable-Circuit-Egg-Incubator-Timer-Relay-Module-Controller-Lahore-Faislabad-Multan-Quetta.jpg?v=1702675828\" data-files=\"Digital-LED-Display-Programmable-Circuit-Egg-Incubator-Timer-Relay-Module-Controller-Lahore-Faislabad-Multan-Quetta.jpg\"\u003e\u003c\/p\u003e\r\n\r\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/digilog.pk\/cdn\/shop\/files\/Digital-LED-Display-Programmable-Circuit-Egg-Incubator-Timer-Relay-Module-Controller-Lahore-Faislabad-Multan-Quetta.webp\" data-original=\"https:\/\/hallroad.digilog.pk\/images\/detailed\/36\/Digital_LED_Display_Programmable_Circuit_Egg_Incubator_Timer_Relay_Module_Controller_Lahore_Faislabad_Multan_Quetta_Sargodha_Rahim_Yar_Khan_Sialkot_Sahiwal_Karachi_Islamabad_Pakistan__4_.jpg\" alt=\"Digital Led Display Programmable Circuit Egg Incubator Timer\" loading=\"lazy\" data-files=\"Digital-LED-Display-Programmable-Circuit-Egg-Incubator-Timer-Relay-Module-Controller-Lahore-Faislabad-Multan-Quetta.webp\"\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e \u003c\/p\u003e\r\n\r\n\u003cp\u003e \u003c\/p\u003e\r\n\r\n\u003ctable style=\"color:#000000; font-family:Arial; font-size:medium; font-style:normal; font-variant-ligatures:normal; font-variant-caps:normal; font-weight:400; letter-spacing:normal; orphans:2; text-align:left; text-transform:none; white-space:normal; widows:2; word-spacing:0px; -webkit-text-stroke-width:0px; background-color:#ffffff; text-decoration-style:initial; text-decoration-color:initial; border:undefined\" width=\"100%\"\u003e\r\n\t\u003ctbody\u003e\r\n\t\t\u003ctr\u003e\r\n\t\t\t\u003ctd class=\"plaintext proddesc\" style=\"line-height: 16px; background-color: rgb(255, 255, 255); text-align: center;\"\u003e\u003cspan style=\"font-size:14px\"\u003e\u003cspan style=\"color:#265a6a\"\u003e\u003cspan style=\"font-family:Ubuntu, sans-serif\"\u003e\u003cspan style=\"font-weight:400\"\u003e\u003cbr class=\"Apple-interchange-newline\"\u003e\r\n\t\t\t\u003ciframe allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/p9u8lrsRrWE\" width=\"560\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\r\n\t\t\t\u003ca href=\"https:\/\/www.mpja.com\/download\/35238mpdata.pdf\" target=\"new\" title=\"Data sheet\" aria-label=\"Visit a webpage about Data sheet\"\u003e\u003cimg alt=\"View PDF Data Sheet\" src=\"https:\/\/digilog.pk\/cdn\/shop\/files\/button-pdfDS.jpg\" style=\"width:100px; height:62px\" data-original=\"http:\/\/www.mpja.com\/images\/button-pdfDS.jpg\" loading=\"lazy\" data-files=\"button-pdfDS.jpg\"\u003e\u003cleft\u003e\u003cbr\u003e\r\n\t\t\t\u003cfont size=\"1\"\u003eDATA SHEET\u003c\/font\u003e\u003c\/left\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\t\t\u003c\/tr\u003e\r\n\t\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\r\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e","brand":"China","offers":[{"title":"Default Title","offer_id":43962458898497,"sku":"B97,KRT39,IMP100,Th50,S","price":550.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/2805\/1777\/files\/6-30V_1-Channel_Power_Relay_Module_with_Adjustable_Timing_Cycle_bc9aafe9-0312-47e4-a9fd-c0f092b81919.jpg?v=1779565459","url":"https:\/\/stem.pk\/products\/timer-relay-6-to-30v-adjustable-timer-delay-timer","provider":"stem.pk","version":"1.0","type":"link"}